Pipelines#
All fields are required unless otherwise stated in the description.
Apacs2FA#
The Apacs2FA pipeline implements custom two-factor authentication for the Apacs service. Listening to events that occurred when reading the card, as well as face detection events. They are matched by their source. When the first factor arrives with a certain source, then the second factor starts waiting, the time for waiting for it is set in the expiry_time setting, as soon as it is received, the validation of this pair begins.
- The similarity of the best matching candidate must not be lower than that specified in the min_similarity setting.
- The card number received from the reader must match the card number of the person in the Luna list.
Upon completion of the authentication procedure, the corresponding text is displayed on the screen of the device. After successful validation, the card number is sent to the corresponding output of the Gate Ethernet Wiegand controller.
To create a pipeline, you need to specify:
Parameter | Description | Possible values | Default value |
---|---|---|---|
name | Pipeline name set by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters. | - |
luna_id | Dropdown list to select the Luna Service ID in Access. | - | - |
apacs_id | Drop-down list to select the APACS service ID in Access. | - | - |
expiry_time | Time limit in seconds to get the second factor. | 0...10 | 5 |
min_face_similarity | Minimum face similarity threshold when performing verification. | The value is formed at the design stage and corrected at the testing stage. | 0.00...1.00 |
unknown_card_message | Message when sending an unknown card to make an access decision. | Any text names. Only Latin characters are supported. It is not recommended to enter more than 50 characters. | The card has been read and sent to the controller |
waiting_time_exceeded_message | Message when the second factor timed out | Any text names. Latin and Cyrillic input is supported. It is not recommended to enter more than 50 characters. | Timeout exceeded |
access_denied_card | Card number of the user created to notify about unsuccessful passes. You must specify the number so that in the connected ACS you can see the log that the authorization failed. | - | None |
use_cards_without_face | Using and sending to the controller cards that are not linked to faces | On - send | On |
Off - do not send |
CreateBastionEvent#
The pipeline listens to LunaEvent
event queue in Luna and generates a BastionEvent event. Works with the Bastion ACS.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
luna_id | Drop-down list with Luna service IDs in Access | - | - |
bastion_id | The unique ID of the Bastion device used in the integration. Specified in Access. | - | - |
min_face_similarity | Minimum face similarity threshold when performing verification | The value is formed at the design stage and corrected at the testing stage (0,00...1,00) | 0,7 |
retry_delay_sec | Pause for reattempting the passage | 1...15 | 5 |
Custom2FA#
The Custom2FA pipeline implements custom two-factor authentication. Card swiping events are listened to, as well as regular face detection events. Events are matched by their source and saved to the mapping. When the first factor arrives with a specific source, the waiting for the second factor starts. The time for waiting for it is set in the expiry_time setting, as soon as it is received, the validation of this pair begins:
- the similarity of the best matching candidate must not be lower than that specified in the min_face_similarity setting;
- the card number received from the reader must match the card number of the face in the Luna list.
When the authentication procedure is completed, the corresponding text is displayed on the screen of the device. After successful validation, the card number is sent to the corresponding controller Gate Ethernet Wiegand or WGNetConverter output.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name set by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters. | - |
luna_id | Dropdown list to select the Luna Service ID in Access. | - | - |
expiry_time | Time limit in seconds to get the second factor. | 0...10 | 5 |
min_face_similarity | The minimum quality value of a recognized face, at which identification will be carried out. The lower the quality, the higher the probability of false positives. | 0.0...1.0 | 0.7 |
unknown_card_message | Message when sending an unknown card to decide on access | Any text names. Only Latin characters are supported. It is not recommended to enter more than 50 characters. | The card has been read and sent to the controller |
waiting_time_exceeded_message | Message when the second factor timed out | Any text names. Latin and Cyrillic input is supported. It is not recommended to enter more than 50 characters. | Timeout exceeded |
use_cards_without_face | Using and sending to the controller cards that are not linked to faces | On - send | On |
Off - do not send |
LunaEventListener#
LunaEventListener listens events from Luna generated by Luna internal service, LunaStreams, or any other external software. Launches controllers of event components (event authors) or launches the functionality of controllers connected to components or taken by name.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
luna_id | Luna service ID in the system | - | - |
min_face_similarity | Minimum face similarity threshold when performing verification. | The value is formed at the design stage and corrected at the testing stage. | 0.00...1.00 |
enable_fake_events | Handling requests with failed Liveness checks to view such events. For activation, the enable_fake_events parameter in the SendToLuna pipeline must be active |
On - handle | Off |
Off - do not process |
MatchByPhotoInCbs#
Requests a descriptor in the CBS and, using its identifier, retrieves a candidate from its database. An event is created with the received data (candidate and source name) and sent to the SuccessMatchEvent queue.
When working with controllers/devices, it is necessary to connect pipelines SendToController/SendToDevice
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
bio_system_id | Unique CBS service identifier | - | - |
pacs_id | UUID of the ACS service in Access | UUID | - |
min_face_similarity | Minimum face similarity threshold when performing verification. | The value is formed at the design stage and corrected at the testing stage. | 0.00...1.00 |
MatchInformerWebHook#
Monitors events from a biometric system (LP5 or CBS), retrieves candidate information and sends it to an external service via a webhook. If no candidate is found, returns an empty best_candidate
value.
The pipeline is required for solutions where Access needs to pass data from related components to external systems beyond the proposed integrations.
The template of the returned data:
{
source: str, best_candidate:
{
person_id: str, similarity: float | None = None, fullname: str | None, descriptor_id: str | None = None
}
}
- source - device name;
- best_candidate - candidate data;
- person_id - candidate ID in ACS;
- similarity - similarity coefficient (only for LP5);
- fullname - candidate full name;
- descriptor_id - descriptor ID;
Для создания пайплайна требуется указать:
Parameter | Description | Possible values | Default value |
---|---|---|---|
name | Pipeline name specified by the user | Any text names. Latin and Cyrillic characters are supported. It is not recommended to enter more than 30 characters. | - |
host | IP address or domain name of the target server | IP address in the form X.X.X.X. or site.domain. | - |
port | Target server port | - | - |
min_face_similarity | Minimum face similarity threshold for verification. | The value is generated at the design stage and adjusted at the testing stage. 0.00...1.00 | 0.7 |
urn | urn for connecting to an external service | - | - |
enable_ssl | Data encryption method for network transmission. Depends on the network type in the solution. | On - https | Off |
Off - http |
MatchInformerWebHook#
Listens for LunaEvent
and ResultMatchEvent
events from a biometric system (LP5 or CBS), retrieves candidate information and sends json to all connected clients via websocket. If no candidate is found, returns an empty best_candidate
value. For authentication, you must add the "Authentication" header with the token from the component information.
The pipeline is needed for solutions where Access needs to pass data from related components to external systems beyond the proposed integrations.
The template of the returned data:
{
source: str, best_candidate:
{
person_id: str, similarity: float | None = None, fullname: str | None, descriptor_id: str | None = None
}
}
- source - device name;
- best_candidate - candidate data;
- person_id - candidate ID in ACS;
- similarity - similarity coefficient (only for LP5);
- fullname - candidate full name;
- descriptor_id - descriptor ID;
To create a pipeline, you need to specify:
Parameter | Description | Possible values | Default value |
---|---|---|---|
name | Pipeline name specified by the user | Any text names. Latin and Cyrillic characters are supported. It is not recommended to enter more than 30 characters. | - |
host | IP address of the server on which Access is installed | IP address in the form X.X.X.X. or site.domain | - |
port | Port of the server on which Access is deployed | - | 9091 |
min_face_similarity | Minimum threshold of face similarity during verification. | The value is generated at the design stage and adjusted at the testing stage. 0.00...1.00 | 0.7 |
SendCardToR20Face#
Listens to the LunaEvent queue, validates the received event for the presence of a candidate, the similarity level, and the presence of a card number. Then, it performs a search for the device based on the event source name, and sends the card number to that device.
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
SendCarsToLaurent#
A pipeline for sending events from LunaCars to Laurent. Listens to the Event
event queue and generates SigurCarEvent events.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
controller_id | UUID of Laurent controller in Access | - | - |
relay_{N}_scenario_id | UUID Scenario in LUNA CARS Analytics, according to which the license plate is checked for the relay {N}. | - | - |
SendCarsToSigur#
A pipeline for sending events from LunaCars to Sigur. Listens to the Event
event queue and generates SigurCarEvent events.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
SendThermalEventToLuna#
Listens to the heat detection event queue and generates events in Luna. To launch, specify the component_id of the Luna service running in the system. The pipeline works with several lists: default list and blacklist. It distributes the received data between lists depending on the set thresholds for the lower and upper temperature values.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
luna_id | Luna service ID in the system | - | - |
handler_id | UUID of the passage event handler, created in Luna | - | - |
black_list_id | Luna list ID with which the device will synchronize people who are denied access (optional) | The ID of the list created in Luna | - |
to_high_temperature | The upper threshold of a person's temperature at which a person cannot be allowed to pass | 3## 37 | |
to_low_temperature | The lower threshold of a person's temperature at which a person cannot be allowed to pass | 3## 35 | |
use_lists | On — match; | Off | |
Off — do not match | |||
min_face_similarity | Minimum face similarity threshold when performing verification. | The value is formed at the design stage and corrected at the testing stage. | 0.00...1.00 |
SendToBars#
Listens to the LunaEvent
, DoorEvent
event queues and generates the BarsEvent
event.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
luna_id | Drop-down list with Luna service IDs in Access | - | - |
bars_host | IP address or network name of the PC with installed Bars server | - | - |
bars_port | Bars server port | ||
enable_ssl | Method of data encryption during transmission over the network. Depends on the type of network in the solution. | On - https | Off |
Off - http | |||
retry_delay_sec | Pause for reattempting the passage | 1...10 | 5 |
min_face_similarity | Minimum face similarity threshold when performing verification | The value is formed at the design stage and corrected at the testing stage (0,00...1,00) | 0,7 |
SendToController#
Sends a signal to open the relay to the device by the name of the event source and displays the text on the screen.
When creating a new pipeline, the following settings are used:
Parameter | Description | Possible values | Default value |
---|---|---|---|
name | User-defined pipeline name | Any text names. Latin and Cyrillic characters are supported. It is not recommended to enter more than 30 characters. | - |
SendToDevice#
Sends a signal to open the relay to the device by the name of the event source and displays the text on the screen.
When creating a new pipeline, the following settings are used:
Parameter | Description | Possible values | Default value |
---|---|---|---|
name | User-defined pipeline name | Any text names. Latin and Cyrillic characters are supported. It is not recommended to enter more than 30 characters. | - |
successful_pass_message_template | Message on successful identification. To display the username on the terminal screen upon successful identification, you must use the full name variables. The order of words in the greeting message can be any. | Any text names and Full name variables. Only Latin characters are supported. It is not recommended to enter more than 33 characters | Welcome! |
unsuccessful_pass_message_template | Message on unsuccessful identification. To display the username on the terminal screen upon successful identification, you must use the full name variables. The order of words in the greeting message can be any. | Any text names. Only Latin characters are supported. It is not recommended to enter more than 33 characters | Face is not identified |
SendToLuna#
The pipeline sends the received FaceDetectionEvent
events to Luna.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
luna_id | Luna service ID in the system | - | - |
enable_fake_events | Submitting faces with failed liveness to view Liveness hack attempts. To activate, the enable_fake_events parameter in the LunaEventListener pipeline must be active |
On - send | Off |
Off - do not send |
SendToParsec#
Listens to LunaEvent
event queue in Luna and generates the ParsecEvent event.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
luna_id | Drop-down list with Luna service IDs in Access | - | - |
parsec_id | Unique ID of the Parsec device used in the integration.Specified in Access | - | - |
retry_delay_sec | Pause for reattempting the passage | 1...10 | 5 |
min_face_similarity | Minimum face similarity threshold when performing verification | The value is formed at the design stage and corrected at the testing stage (0,00...1,00) | 0,7 |
SendToSalto#
Listens to the queue of LunaEvent, in case of successful face validation from the event, sends request to the Salto service to pass through the access point and displays the result of successfull/unsuccessfull pass on the screen of device.
When creating a new pipeline, the following settings are used:
Parameter | Description | Possible values | Default value |
---|---|---|---|
name | Pipeline name set by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters. | - |
min_face_similarity | Minimum face similarity threshold when performing verification. | The value is formed at the design stage and corrected at the testing stage. | 0.00...1.00 |
SendToSigur#
Listens to LunaEvent
event queue in Luna and generates the SigurEvent event.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
luna_id | Drop-down list with Luna service IDs in Access | - | - |
sigur_id | Unique ID of the Sigur device used in the integration. Specified in Access | - | - |
retry_delay_sec | Pause for reattempting the passage | 1...10 | 5 |
SendToStrazh#
If the controller is not in 2FA mode: Listens to the LunaEvent
event queue, in case of successful face validation in the event, sends a request to the Strazh service to pass through the access point.
If the controller is in 2FA mode: Events that occurred when reading the card are listened to, as well as regular face detection events. They are matched by their source
. When the first factor arrives with a certain source, then the second factor is waited for, the time for waiting for it is set in the second_factor_expiry_time
setting, as soon as it is received, the validation of this pair begins.
The following settings are used when creating a new pipeline:
Parameter | Description | Values | Default value |
---|---|---|---|
name | Pipeline name given by the user | Any text names. Only Latin characters are supported. It is not recommended to enter more than 30 characters | - |
strazh_id | Dropdown list to select Strazh service ID in Access. | - | - |
min_face_similarity | Minimum face similarity threshold when performing verification | The value is formed at the design stage and corrected at the testing stage (0,00...1,00) | 0,9 |
waiting_time_exceeded_message | Message when the second factor timed out | Any text names. Latin and Cyrillic input is supported. It is not recommended to enter more than 50 characters. | Timeout exceeded |