Skip to content

Gate ACS#

The integration module (sync.exe), launched in the Gate Server directory, detects changes in the database and sends changes to the ip:port specified in the .env settings file. VL Access accepts and processes these requests, and makes appropriate changes to the Luna list.

Supported versions: Gate Terminal 1.22.95, Gate Server 1.22.95

Supported integration options for Gate ACS#

The face recognition device generates an event, Access passes the event to LP5, LP5 processes the event and returns the result to Access for further processing.

Transfer of user data from the ACS to LP5 occurs using two mechanisms:

  • replication - the mechanism for the initial transfer of user data;
  • synchronization - the mechanism for periodic transfer of user data when the composition/data of users changes.

For the synchronization/replication settings, see the service settings.

Each integration with LP5 (Table 44) uses the Luna service.

If the terminal does not have data output facilities (e.g., a screen), the SendToDevice pipeline is not required.

Table 44. LP5 integration options

Service Device Pipeline
Gate + GateController / PusrController Beward LunaEventListener + SendThermalEventToLuna/SendToLuna
BioSmart LunaEventListener + SendToLuna
Dahua LunaEventListener + SendToLuna
Dahua Thermo LunaEventListener + SendThermalEventToLuna
Fortuna315 LunaEventListener + SendThermalEventToLuna
HikvisionCamera LunaEventListener + SendToLuna
HikvisionCamera Thermo LunaEventListener + SendThermalEventToLuna
HikvisionTerminal Thermo LunaEventListener + SendThermalEventToLuna
LunaFast4A1 LunaEventListener + SendToLuna
Panda LunaEventListener + SendThermalEventToLuna
UniUbi LunaEventListener + SendThermalEventToLuna/ SendToLuna
VKVision02 LunaEventListener
R20Face LunaEventListener + SendToLuna